Size
Contact Spacing
Polarisation
Operating Current
Operating Voltage
Withstand Voltage
Insulation Resistance
Contact Resistance
Operating Temperature
Insulation Material
Contact Material
Contact Finish
Insertion Force
Withdrawal Force
Contact Retention
Mechanical Endurance
|
Form HE-11 - 32, 48, 64, 96
2.54 / 5.08 mm .
Connector shape
3A max. at 85°C
350V DC or AC peak
1000V rms between contacts and 1550V rm between
contact and
ground for one minute.
5000 Mohm min.
15 mohms max.
-55°C to +125°C
Flame retardant thermoplastic UL94V-O
Copper alloy
Contact zone - selectively gold plated termination zone - tin lead or gold
96 Way < 90 N
64 Way < 60 N
48 Way < 45 N
32 Way < 30 N
96 Way > 15 N
64 Way > 10 N
48 Way > 9 N
32 Way > 5 N
Male 20 N Min.
Level I 500 Cycles
Level II 400 Cycles
Level III 50 Cycles |