Size :
Contact spacing :
Polarisation :
Operating voltage :
Operating voltage :
Withstand voltage :
Insulation resistance :
Contact resistance :
Operating temperature :
Insulation material :
Contact material :
Contact finish :
Insertion force :
Withdrawal force :
Contact retention :
Performance class : |
Form R – 32, 48, 64, 96
Form R/2 – 16, 32, 48
Form M -24 + 8
2.54 / 5.08 mm.
Connector shape
3A max. at 85°C
350V DC or AC peak
1000V rms. Between contacts and 1550V rms between contact and ground for one minute.
5000 Mohm min.
15 mohms max.
-55°C to +125°C
Flame retardant thermoplastic (UL94V-O)
Copper alloy
Contact zone – selectively gold plated
Termination zone – selectively gold plated
96 Way < 90 N
64 Way < 60 N
48 Way < 45 N
32 Way < 30 N
96 Way > 15 N
64 Way > 10 N
48 Way > 9 N
32 Way > 5 N
Male 20 N min.
Performance Class I - 500 cycles
Performance Class II - 400 cycles
Performance Class III - 50 cycles
|