Product Specifications |
|
Parameter |
EPS-60-24 |
EPS-50-24 |
EPS-100-24 |
EPS-200-24 |
EPS-240-24 |
Switching Frequency
|
50 Khz. |
25Khz. |
25Khz. |
25Khz. |
25Khz. |
|
Input Voltage Range |
Universal
(85-270 V AC) |
85-130V AC or 190V – 270V AC
(Selectable by inbuilt Switch)
|
|
Inrush current
|
25A at 115V input, 50A at 230V input |
Output voltage and
adjustable range |
24V DC (+/- 10%) |
|
Output Voltage Ripple
|
150 mV pk-pk |
|
Leakage Current |
Less than 3.5 mA at 230 V AC |
|
Output Current Range |
0-2.5A |
0-2.1A |
0-4.5A |
0-8.3A |
0-10A |
|
Efficiency |
79% |
78% |
83% |
83% |
82% |
|
Over Load Protection |
135-150% |
135-150% |
135-150% |
115-135% |
115-135% |
Dimensions (LxWxH) mm.
|
159x97x38 |
159x97x38 |
199x98x38 |
215x115x50 |
215x115x50 |
|
Mounting Screws |
3-M3 |
3-M3 |
3-M3 |
4-M4 |
4-M4 |
|
Cooling |
Free Air convection cooling |
Forced Air cooling with inbuilts Fan |
|
Weight |
510 g. |
510 g. |
620 g. |
930 g. |
1150 g. |
|
|
|
|
|
|
|
|
Product Specifications |
|
Parameter |
EPS-15-5 |
EPS-100-5 |
EPS-40-12 |
EPS-100-12 |
EPS-145-12 |
EPS-145-24 |
Switching Frequency
|
36 Khz. |
25Khz. |
36Khz. |
25Khz. |
25Khz. |
25Khz. |
|
Input Voltage Range |
85-130 V AC or 190V – 270 V AC
(Selectable by inbuilt Switch) |
Universal
(85-270 V AC) |
85-130 V AC or 190V-270 AC
(Selectable by inbuilt Switch) |
|
Inrush current
|
25A at 115V input, 50A at 230V input |
Output voltage and
adjustable range |
5V DC
(-5 to +10%) |
5V DC
(-5 to + 10%) |
12V DC
(+/-10%) |
12V DC
(+/-10%) |
12V DC
(+/-10%) |
24V DC
(+/-10%) |
|
Output Voltage Ripple
|
150 mV pk-pk (maximum) |
|
Leakage Current |
3.5 mA at 230 V AC (maximum) |
|
Output Current Range |
0-3A |
0-20A |
0-3.5A |
0-8.5A |
0-12A |
0-6A |
|
Efficiency |
65% |
78% |
76% |
81% |
83% |
80% |
|
Over Load Protection |
115-150% |
135-150% |
115-150% |
135-150% |
135-150% |
135-150% |
Dimensions (LxWxH) mm.
|
99x97x36 |
199x98x38 |
129x98x38 |
199x98x38 |
199x98x38 |
199x98x38 |
|
Mounting Screws |
2-M3 |
3-M3 |
2-M3 |
3-M3 |
3-M3 |
3-M3 |
|
Cooling |
Free Air convection cooling |
|
Weight |
310 g. |
620 g. |
440 g. |
620 g. |
710 g. |
710 g. |
|
|
|
|
|
|
|
|
|
Note :
(A) For proper cooling of the power supply ensure a clearance of at least 2.0 cm
on the top and at least one side of the power supply.
(B) Load regulation and line regulation are +/-2% for +5V DC output SMPS (instead
of 1%)
(C) Overload protection for 145W SMPS is shutdown type and recovery is not automatic
when overload is removed.
Input power has to be ogled off then on to get power
again for SMPS.
|
|
|
All dimensions are in mm.
Due to continuous improvement in products, we reserve the right to alter specifications
without prior notice. |
|
|
|
Previous1234Next |