Technical Data |
|
Input voltage: |
85-130V AC/190-270V AC(selectable by inbuilt switches) |
|
Output voltage: |
24V DC or 12V DC or 5V DC, Adjustable upto +/- 10% with inbuilt Potentiometer |
|
Line regulation: |
Better than 1% from low line to high line |
|
Load regulation: |
Within 1% of output from 0% to 100% rated load |
|
Efficiency: |
About 82% at full load |
|
Protection: |
Over-load protection 125-135% Short circuit protected, automatic recovery when short circuit removed |
|
Leakage current: |
Less than 3.5mA at 230V AC input for all models |
|
Inrush current: |
25A to 110V, 50A at 230V |
|
Isolation: |
1500VAC for 1 minute between input and output
1500VAC for 1 minute between Input and Safety Earth
5000VAC for 1 minute between Output and Safety Earth |
|
Insulation Resistance: |
Tested for 100 Mohms at 500VDC |
|
Wire Connections: |
12-22 AWG cable connection on 9.5mm pitch Terminal Block |
|
EMI/EMC: |
Tested according to EN55022 Class B |
|
Enclosure Material: |
Chassis- Aluminium. Cover- Steel with corrosion resistant plating |
|
Hold Time: |
At least 20 msec at rated load |
|
Mounting: |
3 M3 screws (Side Mounting), 4 M3 screws(Bottom mounting) |
|
Temprature: |
Storage Temprature: -20 to 95 degree C. Working temprature 10 to 650C |
|
Warranty: |
18 months from the date of purchase |