- Pulsed Interval timer is designed for applications such as hand dryers which utilise
a momentary push button to produce an interval period.
- The load current is fed from an isolated set of contacts which prevents the current
from passing through the push button and hence light duty contacts may be used.
- On application of the supply voltage, no operation occurs. After momentary actuation
of the external push button, the relay energises for the set period.
|
|
|
SPECIFICATIONS |
Supply voltage:
Power consumption
Time range
Scale accuracy
Repeat accuracy
Temperature range
Electrical life
Contact rating
Initiation pulse
Initiation current
|
110, 230V AC, 24V DC
4 VA maximum
1,2,5,10,30,60 seconds
2,5 minutes
±5% of range
±1 % of range
-10°C to +60°C
1,00,000 operations
15 amp at 240V AC resistive load
20 milliseconds minimum
10mA at 24V DC
|
|
Ordering Code |
Number of Change
over contacts:
|
Series
|
Base Configuration |
Mode |
Time range |
Supply voltage |
|
1 |
K |
B |
PIT |
60S |
230V AC |
|
|
|
B: 8 Pin base
|
Star Delta |
1,2,4,10,30
& 60S(Seconds)
2& 5M(Minutes) |
110 & 230V AC 24V DC |
|
|
|
|
|
|
|
|
|
|
Previous123456789101112131415161718Next |
|
|
|
|
|
|